The emission filter is a critical part of any fluorescence system (learn more about fluorescence filters here). Emission filters, and to a lesser extent excitation filters, provide most of the signal-to-noise ratio (SNR) enhancement in fluorescence systems. This note describes emission filters and their use in both single-point (as in photometry and point-scanning) and imaging (microscopic and macroscopic) applications.
Full story
How can you improve data quality and reliability in your fluidic system? Consider the DGC-020 degassing chamber by IDEX Health & Science. Learn more from this data sheet.
Full story
Changes in pressure, temperature, or reagent mixing cause bubbles to outgas into the flow path, creating inaccurate aspiration and dispense functions as well as disrupting optical detection. Learn how this degassing chamber works and how it can create optimal performance for aqueous chemistries at flows of 5-20mL/MIN (80–330 µL/SEC).
Full story
IDEX Health & Science | Semrock has been delivering the ultimate in fluorescence filters for over 20 years. Our ultra-steep transition edges, deep blocking, and high
transmissions have set the standard for excellence and have helped drive the creation of new, higher performance optical systems. In this Tech Note, you will learn to use our unique products to get the most out of your fluorescence and Raman excitation designs, no matter what the light source.
Full story
Download technical information, specifications, and product inserts for the Nanopede filter family Flight 1 and 2 sets.
Full story
When it comes to high-precision tubing, our manufacturing team is fully equipped to construct to your exact specifications, saving you time and complexity. Download our new brochure to learn more about our tubing capabilities.
Full story
Consolidating multiple flow paths into one cohesive unit, a manifold is an integral part of reliable instrument performance. Learn more in this brochure.
Full story
When you are developing optical instrumentation, you continually face new challenges: new customer requirements and product expectations, evolving technologies, changing markets, and the need for a rapid and decisive response. To help you conquer those challenges, Semrock provides superior products and expert, personalized support. Learn more in our brochure.
Full story
Adeptly meet the lifetime requirements of your workflow with IDEX Health & Science
fluidic control valves. Learn more in this brochure.
Full story
In the world of high-quality optical filters, where precision is paramount, the ability to tailor parts to your exact requirements is essential. At IDEX Health & Science, we offer a range of Semrock™ optical filters to meet your specific needs. This guide will introduce you to the available customization options.
Full story
Unsure if catalog, custom, or hybrid optical filters are right for your project? Explore our step-by-step guide to find the best Semrock optical filter for your application.
Full story
Optical thin-film coatings can be deposited by a variety of methods. Traditionally the most popular methods for depositing multilayer coatings – required for higher-performance mirrors and filters – include thermal and electron-beam (e-beam) evaporation and ion-assisted e-beam evaporation (IAD). Learn more in this tech note.
Full story
Optical Density – or OD, as it is commonly called – is a convenient tool to describe the transmission of light through a highly blocking optical filter (when the transmission is extremely small).
Full story
Notch filters are ideal for applications that require nearly complete rejection of a laser line while passing as much non-laser light as possible. The main drawback of standard thin-film notch filters has been a limited passband range due to the fundamental and higher-harmonic spectral stop bands.
Full story
The Semrock MaxLine and RazorEdge U-grade optical filters make an ideal filter pair for applications like Raman spectroscopy – they fit together like hand-in-glove.
Full story
Due to limitations of standard metrology techniques, the measured spectral characteristics of thin-film interference filters are frequently not determined accurately, especially when there are steep and deep edges. Learn more about IDEX Health & Science | Semrock's solution to measure optical filter spectra.
Full story
The Pressure Relief Valves and Pressure Relief Tee are supplied with Flangeless Fittings for 1/16” OD tubing. Learn how to connect your tubing to the inlet and outlet of the valve tee using the included fitting and more.
Full story
Unlock the full potential of your clinical laboratory platform by partnering with IDEX Health & Science to access cutting-edge fluidic technology and a team of dedicated experts to develop your optimal fluidic system.
Full story
IDEX Health & Science makes a wide variety of 45º dichroic beamsplitters optimized for different purposes. Learn more about selecting the right dichroic beamsplitter.
Full story
With its quick and simple press-fit design, BioTight™ is as straightforward to assemble as it is to use. Download our new guide to view its benefits and operating instructions.
Full story